NovaScale R620 User Guide
7-6
On-screen error message
Cause
Action
0B96 BMC SDR Repository
failure
SDR repository within BMC is
faulty.
0B97 BMC SEL device
failure
SEL repository within BMC is
faulty.
0B98 BMC RAM test error
BMC RAM is faulty.
0B99 BMC Fatal hardware
error
BMC FPGA is faulty.
If updating FPGA does not help, replace the CPU/IO
module or ft Remote Management Card (option).
0B9A BMC not responding
BMC device is faulty.
Replace the CPU/IO module or ft Remote
Management Card (option).
0B9B Private I2C bus not
responding
I2C bus is faulty.
Replace the part related to failed I2C bus.
0B9C BMC internal
exception
0B9D BMC A/D timeout error
BMC device is faulty.
Replace the CPU/IO module or ft Remote
Management Card (option).
0B9E SDR repository corrupt SDR data is faulty.
If updating SDR does not help, replace the CPU/IO
module or ft Remote Management Card (option).
0B9F SEL corrupt
SEL repository within BMC is
faulty.
Replace the CPU/IO module or ft Remote
Management Card (option).
0BA0 SDR/PIA mismatched.
SDR, PIA must be
updated.
SDR and PIA data do not
match.
If updating SDR/PIA does not help, replace CPU/IO
module or ft Remote Management Card (option).
0BB0 SMBIOS - SROM data
read error
I2C bus is faulty.
SROM is faulty.
BMC is faulty.
0BB1 SMBIOS - SROM data
checksum bad
Data within SROM is faulty.
If turning AC power off and on does not help, replace
the CPU/IO module.
0BC0 POST detected
start-up failure of 1st
Processor
0BC1 POST detected
start-up failure of 2nd
Processor
CPU is faulty.
Replace the CPU.
8120 Unsupported DIMM
detected in DIMM
group #1
8121 Unsupported DIMM
detected in DIMM group #
8122 Unsupported DIMM
detected in DIMM group
#3
Unsupported DIMM is
mounted.
8130 Mismatch DIMM detected
in DIMM group#1
8131 Mismatch DIMM detected
in DIMM group#2
8132 Mismatch DIMM detected
in DIMM group#3
DIMM group do not match.
Check supported DIMMs and replace the DIMM. If
replacing the DIMM does not help, replace the
CPU/IO module.
8150 NVRAM Cleared By
Jumper
CMOS clear jumper is
mounted.
8151 Password Cleared By
Jumper
Password clear jumper is
mounted.
Turn off the DC power and change back the jumper
setting.
8160 Mismatch Processor
Speed detected on
Processor 1
8161 Mismatch Processor
Speed detected on
Processor 2
CPU frequency does not
match.
8170 Processor 1 not
operating at intended
frequency.
CPU frequency is incorrect.
Check supported CPUs and replace the CPU. If
replacing the CPU does not help, replace CPU/IO
module.
8171 Processor 2 not
operating at intended
frequency
CPU frequency is incorrect.
Check supported CPUs and replace the CPU. If
replacing the CPU does not help, replace CPU/IO
module.
Summary of Contents for Bull NovaScale R620 Series
Page 1: ...User s Guide Bull NovaScale R620...
Page 2: ......
Page 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Page 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Page 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Page 345: ...This page is deliberately left empty...
Page 346: ......