![background image](http://html1.mh-extra.com/html/nec/bull-novascale-r620-series/bull-novascale-r620-series_user-manual_3916556285.webp)
NovaScale R620 User Guide
7-23
Warning message appears in POST after implementing ft Remote Management Card (R620-LR model
only):
Did you set
“
Initialize Remote Management Card
”
?
H/W Configuration of BMC is corrupted.
!! Update BMC H/W Configuration by configuration tool!!
!! Refer to BMC Configuration manual !!
If the message above appears, press
F1
key or wait for a while. Then POST proceeds. Insert
EXPRESSBUILDER CD-ROM attached to the server into the CD-ROM drive to start
EXPRESSBUILDER. Select [Tools] - [Initialize Remote Management Card] from its main menu to
write the sensor information specific to the server to the card.
NovaScale/ft Server series cannot be recognized from management PC:
Did you add the Remote Management Card (option)?
Start EXPRESSBUILDER attached to the device, and select [Tools]
–
[Initialize Remote Management
Card] from the main menu, and write the information specific to each server to the card.
Is Java2 Runtime Environment, Standard Edition 1.4.2_04 or later applied to management PC?
Java2 Runtime Environment, Standard Edition 1.4.2_04 or later is necessary. It can be installed from
the following location.
Start Windows and insert EXPRESSBUILDER CD-ROM attached to the device into CR-ROM on
management PC where you want to install. Master control menu is displayed by Autorun function.
Execute JRE installer in DianaScope install menu from [Software Setup]
–
[DianaScope].
*Download the latest Java Runtime from http://java.sun.com/j2se/
Is the LAN cable properly connected?
Make sure that LAN cable is properly connected. The device sensor cannot be referred unless the cable
is properly connected. Check if the cable is connected to the LAN connector or serial port connector by
mistake.
Is the IP address shared?
IP address of the management LAN port is set to 192.168.1.1 at the time of shipping. Change the IP
address since it will not be recognized properly if there is same IP address on the same network.
Is the connection restricted by firewall or gateway?
The connection may be restricted by the setting such as firewall. If directly connecting the LAN to
client PC with cross cable can solve the problem, see
“
Network Settings
”
of
“
REMOTE
MANAGEMENT FUNCTION
”
in Chapter 4 and check firewall or gateway again.
The device console screen does not appear in web remote KVM console screen:
Is the resolution setting of the device correct?
R620-LR model
When the device screen is displayed in ft Remote Management Card, change the screen settings to fit
within resolution 1024x768 and refresh rate 75 Hz.
R620-MR model
When the device screen is displayed in remote management function of remote KVM, change the
screen settings to fit within resolution 1024x768 and refresh rate 75 Hz.
Summary of Contents for Bull NovaScale R620 Series
Page 1: ...User s Guide Bull NovaScale R620...
Page 2: ......
Page 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Page 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Page 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Page 345: ...This page is deliberately left empty...
Page 346: ......