NovaScale R620 User Guide
7-7
On-screen error message
Cause
Action
9064 Mixed CPU Steppings
detected
Different CPU steppings are
found.
Check supported CPUs and replace the CPU. If
replacing the CPU does not help, replace CPU/IO
module.
9038 Check date and time
settings (Chipset)
Data and time settings are
incorrect.
9001 Missing date and time
synchronization
Information delivery among
units failed
If reconfiguring by using BIOS setup does not help,
replace the CPU/IO module.
9002 Memory not installed.
DIMM is not implemented.
DIMM is faulty.
Mount or replace the DIMM.
9003 Memory
implementation error
detected
Error is detected on memory
implementation.
Check supported DIMMs and replace the DIMM. If
replacing the DIMM does not help, replace the
CPU/IO module.
9004 Real time clock error
(Chipset)
RTC is faulty.
Reconfigure RTC by using BIOS setup.
9005 Remote BMC access
failed
BMC of remote unit is faulty.
Check again if the CPU/IO module is mounted
properly. If this does not help, replace the CPU/IO
module.
9006 HW Memory Test
failed.
Memory is faulty.
Replace the DIMM. If replacing it does not help,
replace the CPU/IO module.
9009 Chipset NMI occurred!
BIOS NMI handler is executed
and POST is stopped.
Obtain detailed information, and replace the CPU/IO
module.
900A PEXA Link Width
Warning
900B PEXB Link Width
Warning
900D PEXD Link Width
Warning
900E PEXE Link Width
Warning
PCI-EX Link is faulty.
Since performance becomes slightly lower, replace
the CPU/IO module in case of an emergency.
9021 Trace memory test
failed
Trace memory is faulty.
Replace the CPU/IO module.
902C BMCFW major revision
mismatched.
BMCFW revision does not
match.
Update SDR/PIA. If updating it does not help,
replace the CPU/IO module or ft Remote
Management Card (option).
902D IPMB#1 SROM failure
detected
IPMB#1 SROM is faulty.
902E IPMB#2 SROM failure
detected.
IPMB#2 SROM is faulty.
If restarting does not help, replace the CPU/IO
module, ft Remote Management Card (option) or
centre plane.
902F PCI Device Test failed.
PCI Device is faulty.
Replace the CPU/IO module.
9060 Module#0 is not
present.
CPU/IO module#0 is not
mounted.
Mount the primary unit. If restarting does not help,
replace the CPU/IO module.
9061 Module#1 is not
present.
CPU/IO module#1 is not
mounted.
Mount the primary unit. If restarting does not help,
replace the CPU/IO module.
9039 Not keep last boot
order
Unintended operations such
as incorrect DC off are
performed.
Reconfigure the boot option by using the BIOS
setup. If reconfiguring the boot option does not help,
replace the CPU/IO module.
9070 The error occurred
during water-cooling
unit sensor reading
The sensor of water-cooling
kit is faulty.
Replace the water-cooling kit. If turning on/off AC
does not help, replace CPU/IO module or ft Remote
Management Card.
NOTICE System is force
boot with POST
error
Abnormality of one or both
sides of modules is detected.
View other error information and the error
information of standby CPU/IO module.
9000
A serious error occurred
during a POST.
There are some error messages in addition to this
error code.
Check the other error message.
9007
9008
Forced power off occurred by
another CPU/IO module has a
problem.
Pull out another CPU/IO module and install it.
If this does not help, replace the CPU/IO module.
9010
–
9015
Cannot boot from target Disk.
Check the target disk.
In addition, replace it if required.
If this does not help, replace the CPU/IO module.
Summary of Contents for Bull NovaScale R620 Series
Page 1: ...User s Guide Bull NovaScale R620...
Page 2: ......
Page 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Page 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Page 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Page 345: ...This page is deliberately left empty...
Page 346: ......