NovaScale R620 User Guide
7-25
Event Log
"The NMS Service terminated unexpectedly." is recorded in the system event log:
Although the following log may be recorded in the system event log when starting the system, or after
exchanging PCI modules, there is no real problem on operation. Change of a setup with PROSet II
will become invalid if NMS service stops, but you can change a setup normally because NMS service
will be automatically started when PROSet II is started.
“
Source:
Service Control Manager
Event ID:
7031
Description: The NMS service terminated unexpectedly. This has occurred 1 time(s). The following
corrective action will be taken in 0 milliseconds: No action.
”
iANSMiniport-related logs are recorded in the system event log:
The logs of the source
“
iANSMiniport
”
are the logs about the duplex of the network. The following
logs may be recorded in the system event log after starting the system or after setting duplex, but there
is no problem on operation.
Source:
iANSMiniport
Type:
Warning
Event ID:
35
Description: Initializing
“
Virtual Team Adaptor
”
that lack adapter
“
Number of missed adaptors
”
.
Check if all adapters exist and function properly.
Source:
iANSMiniport
Type:
Warning
Event ID:
13
Description:
“
Physical Adaptor
”
is invalid in the team.
Source:
iANSMiniport
Type:
Warning
Event ID:
11
Description: The following adapter link is not connected:
“
Physical Adaptor
”
.
Source:
iANSMiniport
Type:
Error
Event ID:
16
Description:
“
Virtual Team Adaptor
”
: the last adapter lost the link.
The team network lost the connection.
Source:
iANSMiniport
Type:
Warning
Event ID:
22
Description: The primary adapter did not detect the following probe:
“
Physical Adaptor
”
. Reason:
The team may be divided.
The log above gets output in the process of system start up or dual mode setting. When the log is
recorded, there is no problem to the system by the above warning if the status of the adapter in the
team is
“
Active
”
or
“
Standby
”
. For the status of the adapter, check in properties of the team adapter
from the device manager.
EvntAgnt log is recorded in the application event log:
This event does not have any influence to the system not to SNMP services. Thus no measurement is
required.
Source:
EvntAgnt
Event ID:
1003
Description: TraceFileName parameter not located in registry; Default trace file used is .
Source:
EvntAgnt
ID:
1015
Summary of Contents for Bull NovaScale R620 Series
Page 1: ...User s Guide Bull NovaScale R620...
Page 2: ......
Page 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Page 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Page 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Page 345: ...This page is deliberately left empty...
Page 346: ......