![background image](http://html1.mh-extra.com/html/nec/bull-novascale-r620-series/bull-novascale-r620-series_user-manual_3916556104.webp)
NovaScale R620 User Guide
Configuration Examples
The following describes examples of configuration required to use software-link features or for system operations.
Link with Management Software
To control power supply of the server with ESMPRO Manager via the network
<Using the LAN connector on the motherboard>
Select [Advanced]
→
[Advanced Chipset Control]
→
[Wake On LAN]
→
[Enabled]
<Using the PCI LAN card>
Select [Advanced]
→
[Advanced Chipset Control]
→
[Wake On PME]
→
[Enabled]
UPS
To link power supply with the UPS
To power on the server when power is supplied from the UPS
Select [Server] - [AC-LINK] - [Power On].
To keep the server off-powered even when power is supplied from the UPS if the POWER switch was used to
power off
Select [Server] - [AC-LINK] - [Last State].
To keep the server off-powered even when power is supplied from the UPS
Select [Server] - [AC-LINK] - [StayOff].
Keyboard
To set Num Lock and key repeat
Select [Advanced] - [NumLock].
Security
To set passwords on the BIOS level
Select [Security] - [Set Supervisor Password] and enter a password.
Set Supervisor password first, then User password.
To enable/disable the POWER switch
Select [Security] - [Switch Inhibit] - [Disabled]. (POWER switch enabled)
Select [Security] - [Switch Inhibit] - [Enabled]. (POWER switch disabled)
IMPORTANT:
Masking the POWER switch disables forced shutdown as well as power on/off using the POWER switch.
4-5
Summary of Contents for Bull NovaScale R620 Series
Page 1: ...User s Guide Bull NovaScale R620...
Page 2: ......
Page 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Page 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Page 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Page 345: ...This page is deliberately left empty...
Page 346: ......