![background image](http://html1.mh-extra.com/html/nec/bull-novascale-r620-series/bull-novascale-r620-series_user-manual_3916556289.webp)
NovaScale R620 User Guide
7-27
Source:
HAS Fault Tolerance
Type:
Warning
Event ID:
204 - 208
Intermittent failure of software which is attributed to the server load may be the reason for these logs
to be recoded.
The following event logs may be recorded when operating or replacement/maintenance of each device
of network adapter/SCSI disk/fibre channel, but there is no problem in continue operating the system.
However, there might be a problem in OS or software environment if logs are recorded regardless of
following the maintenance procedure or they are recorded repeatedly. Contact your maintenance
service company.
Source:
HAS Fault Tolerance
Type:
Warning
Event ID:
209 - 213
Started maintenance operation without suspending (or stopping) HAS Fault Tolerance service may be
the reason for these logs to be recoded.
If the event ID is 212 or 213, and if
“
The error occurred in the duplex state watchdog of SCSI devices.
Error code: -1
”
or
“
The error occurred in the duplex state watchdog of FC devices. Error code: -1
”
is
registered for the details, applications such as backup software may access the internal log file of HAS
Fault Tolerance service. This event does not affect the duplication operation.
The following event logs may be recorded during the system operation, but there is no problem in
continue operating the system. However, there might be a problem in OS or software environment if
logs are recorded repeatedly. Contact your maintenance service company.
Source:
HAS Fault Tolerance
Type:
Error
Event ID:
300
These logs report captured information when the program exception occur within HAS Fault Tolerance
service. The program exception occurs for various reasons, but HAS Fault Tolerance service has allowance
function that can handle the problem. It is also set to self-recover even when exceeding the allowance range.
HasCtrl-related logs are recorded in the system event log:
The following event logs may be recorded during the system operation. This log shows that CPU
module is not in a dual mode. There is no problem to the system by this warning, since CPU module
will be set to a dual mode again.
Source:
HasCtrl
Type:
Warning
Event ID: 1202
Description: The driver failed the fast re-sync function of the CPU module
[Module[Module Number]]
[Module Number]
“
#0
”
or
“
#1
”
Source:
HasCtrl
Type:
Warning
Event ID: 3500
Description: The error occurred on the CPU module of Module [Module Number].
[Module Number]
“
#0
”
or
“
#1
”
Source:
HasCtrl
Type:
Warning
Event ID: 4000
Description: The error occurred on the CPU module of Module [Module Number].
[Module Number]
“
#0
”
or
“
#1
”
Source:
HasCtrl
Type
Warning
Event ID: 4310
Description: Synchronization of the CPU module stopped.
Summary of Contents for Bull NovaScale R620 Series
Page 1: ...User s Guide Bull NovaScale R620...
Page 2: ......
Page 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Page 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Page 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Page 345: ...This page is deliberately left empty...
Page 346: ......