NovaScale R620 User Guide
Procedure in ESMPRO Manager
1.
Select the target module in the [ft] tree.
2.
Check the current state with the "State" display on the target module screen. If CPU and IO modules of the target
module are running, stop them.
3.
Click the [Diagnostics] button in the [Maintenance] screen for the IO module of the target module.
When the diagnostics is started, the CPU and IO modules are diagnosed together.
The diagnostics result can be confirmed by "Result" of the diagnostics on the target component screen. The result
of the diagnostics is reported by the server as an alert.
The result of diagnostics executed last is displayed in the [Diagnostics Information] column. In addition, if a
fault is detected by the result of the diagnostics, the state of the [General Information] tree of the component is
changed.
CHECK:
When stopping IO module, check that the status of Ethernet is “Duplex” on ESMPRO Manager. Do not stop the IO
module especially when LAN is connected only to the IO module on that side.
Sample screen of ESMPRO Manager
[Maintenance] screen of IO
module
[PCI Module] – [Maintenance]
5-58