NovaScale R620 User Guide
Dump Collection
To collect the dump file with ESMPRO Manager, use [CPU Module]
→
[Maintenance] tree in the data viewer.
To collect the dump with the Server Maintenance Utility, use the utility screen of the component.
IMPORTANT:
Acquire the dump only for the examination of a fault. For the memory dump setting of OS, select “Complete
memory dump” when it is available. The quick dump function of this server is enabled only when the dump
setting is set to “Complete memory dump.”
Perform the steps below to change your memory dump setting, if a total memory capacity exceeds 2GB after
additional memory has been installed in the system with complete memory dump enabled. If the setting is not
changed incorrect dump files may be collected.
1) Go to [Control Panel], click [System], and click [Advanced] to display the [Startup and Recovery] dialog
box. Choose “Small memory dump” and click [OK].
2) Return the setting to “Kernel memory dump” and click [OK].
The dump can be collected in two ways. In each way, the dump file is collected with the same path and file name
"%SystemDrive%MEMORY.DMP" as the dump file of the OS standard.
Collecting dump of inactive module
The dump is acquired from the inactive CPU module (Broken or Shot).
The dump can be collected only when the power is supplied with the module POWER LED illuminating and both
CPU module and IO module are stopped.
Collecting dump under system operation
Either of the CPU modules is entered into the offline state and the dump is collected during system operation. After
the acquisition, the CPU module is returned to the online state again. This can be done only in the duplex system.
The table below shows the potential cases in which the dump is acquired.
Saving dump of stopped module
Saving dump of component under
system operation
Component
Remote Local
Remote
Local
CPU Module
–
When a fault or malfunction
occurs in the system.
Save the dump if requested
by maintenance personnel.
Executable in the following
module state:
(this can be viewed on
Server Maintenance Utility
screen)
•
Removed
•
Broken
•
Shot
•
Firmware Update
Complete
•
Diagnostics Passed
When a fault or
malfunction occurs
in the system.
Save the dump if
requested by
maintenance
personnel.
Executable in the
following module
state (this can be
viewed on manager
screen):
•
Duplex
When a fault or
malfunction occurs in
the system.
Save the dump if
requested by
maintenance
personnel
Executable in the
following module
state:
(this can be viewed on
Server Maintenance
Utility screen)
•
Duplex
Remote: Executable from remote management PC by using ESMPRO Manager
Local:
Executable on local server by using Server Maintenance Utility
–: Not
supported
5-64
Summary of Contents for Bull NovaScale R620 Series
Page 1: ...User s Guide Bull NovaScale R620...
Page 2: ......
Page 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Page 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Page 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Page 345: ...This page is deliberately left empty...
Page 346: ......