NovaScale R620 User Guide
7-36
To request programmatically to remove media from removable disks such as MO, Zip and PD.
Please conduct these works by following the procedure written below.
1.
Open [Control panel]
–
[Service].
2.
Select a service named
“
ESM Common Service
”
and click [Stop].
3.
Confirm that
“
ESM Common Service
”
is stopped, and close the [Service] in [Control Panel].
4.
Do the disk
–
related works.
5.
Open the [Service] in [Control Panel] again. Select
“
ESM Common Service
”
and click the
[Start].
6.
Confirm that
“
ESM Common Service
”
is started and close the [Service] and [Control Panel].
Changing the threshold of temperature/voltage/fan monitoring is desired:
→
Displaying/changing the threshold of the temperature/voltage /fan from ESMPRO Agent is not allowed.
However, you can display the threshold on the data viewer of ESMPRO Manager on some models.
ESMPRO Agent monitors using the appropriate threshold that is set for each model.
The detail information of alert is displayed as
“
Unknown
”
:
→
Detail information of some alert displayed on the alert viewer may be displayed as
“
Unknown
”
.
Monitoring the failures of the tape device is desired:
→
ESMPRO Agent does not monitor the failures of the tape device. If you want to conduct monitoring, use
backup software or tape monitoring application. Using the event monitoring function of ESMPRO
Agent allows you to monitor the event log of backup software or applications.
File system monitoring cannot be inherited on the system using EXPRESSCLUSTER:
→
When using ESMPRO Agent in the cluster environment configured by EXPRESSCLUSTER, there is
the following limitation:
If a failover occurs, the settings of the threshold for the empty space monitoring function and the
enable/disable of monitoring of the operating sever are not inherited to the standby server. Make sure to
reset the threshold and the enable/disable of monitoring on the standby server.
Temperature/voltage/fan sensors appear in an incorrect manner:
Some models are equipped with temperature/voltage/fan sensors that do not have information on
status, current values, rpm, threshold etc. Therefore, if you view such a sensor on ESMPRO Manager,
it may be displayed as follows:
The status becomes
“
Unknown
”
(greyed out) on the data viewer.
The current value or rpm is displayed as
“
Unknown
”
on the data viewer.
The status is greyed out on the Web component data viewer.
The current value or rpm becomes blank on the Web component data viewer.
Even if the sensor is stated like stated above, it is monitoring the server.
Temperature/voltage error occurs on the CPU/PCI modules:
At the time when a temperature or voltage error occurs on CPU/PCI module (CPU/IO module),
necessary actions will differ depending on their status as shown below. You can check the status of
each module from the data viewer of ESMPRO Manager or Server Maintenance Utility.
Status
Operation
Duplex
Stop the failed CPU/PCI module (CPU/IO module).
Simplex
Shut down the system.
If the status is
“
Empty
”
, the module is not mounted. Sensor monitoring is not conducted.
Summary of Contents for Bull NovaScale R620 Series
Page 1: ...User s Guide Bull NovaScale R620...
Page 2: ......
Page 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Page 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Page 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Page 345: ...This page is deliberately left empty...
Page 346: ......