![background image](http://html1.mh-extra.com/html/nec/bull-novascale-r620-series/bull-novascale-r620-series_user-manual_3916556270.webp)
NovaScale R620 User Guide
7-8
On-screen error message
Cause
Action
9020
CPU is faulty.
Replace the CPU.
If this does not help, replace the CPU/IO module.
9022
–
9023
Initialization of the cross-link
between the CPU/IO modules
and access are faulty.
9024
Disconnect the cross-link
between the CPU/IO modules.
When the system is running in the duplex mode, it is
no problem.
If the system cannot be running in the duplex mode
due to continuous this error, replace the CPU/IO
module.
If this does not help, replace another CPU/IO
module or center plane.
9027
Mounted CPU is mismatching.
CPU configuration may be different between the
CPU/IO modules.
Replace the CPU.
If this does not help, replace the CPU/IO module.
9028
Memories of different types
are installed.
Memories of different types are installed.
Replace DIMM with appropriate one.
If this does not help, replace the CPU/IO module.
9029
DIMM is faulty.
Replace DIMM.
If this does not help, replace the CPU/IO module.
902A
Initialization of the cross-link
between the CPU/IO modules
and access are faulty.
When the system is running in the duplex mode, it is
no problem.
If the system cannot be running in the duplex mode
due to continuous this error, replace the CPU/IO
module.
If this does not help, replace another CPU/IO
module or center plane.
902B
BIOS revision does not match.
This BIOS revision cannot support the duplex mode.
Update the BIOS revision.
9031
Configuration of PCI riser is
mismatch.
Check the PCI configuration.
If this does not help, replace the CPU/IO module.
9032
The microcode to CPU is not
found and it cannot update
normally.
Unsupportted CPU may be mounted.
Replace the CPU.
If this does not help, replace the CPU/IO module.
9033
The
microcode
to
CPU
cannot update
normally.
Replace the CPU.
If this does not help, replace the CPU/IO module.
9034
903A
DIMM is faulty.
Replace the DIMM.
If this does not help, replace the CPU/IO module.
9040
–
9047
CPU is faulty.(ID=0-7)
Replace the CPU.
9050
–
9055
DIMM is faulty.(ID=0-5)
Replace the DIMM.
If this does not help, replace the CPU/IO module.
9058 - 905F
This CPU/IO module detected
mismatch of CPUID between
the CPU/IO modules.
CPU configuration may be different between the
CPU/IO modules.
Replace the CPU.
If this does not help, replace the CPU/IO module.
9062
–
9063
CPU/IO module or ft Remote
Management Card (option) is
faulty.
If turning AC power off and on does not help, replace
the CPU/IO module or ft Remote Management Card
(option).
9065
One or both the CPU/IO
modules have a problem.
There are some error messages in addition to this
error code.
Check the other error message.
9071
–
9072
Water-cooling kit has leaked
out.
Replace the water-cooling kit.
If this does not help, replace the CPU/IO module.
Summary of Contents for Bull NovaScale R620 Series
Page 1: ...User s Guide Bull NovaScale R620...
Page 2: ......
Page 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Page 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Page 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Page 345: ...This page is deliberately left empty...
Page 346: ......