NovaScale R620 User Guide
7-15
The keyboard or mouse fails to operate:
Is the cable properly connected?
Make sure that the cable is connected to the correct connector on the rear of the server.
Are the keyboard and mouse are compliant with NovaScale/ft Server series?
Operation of the server with unauthorized devices is not guaranteed.
Does the server have drivers installed?
Refer to the manual that comes with your OS to check that the keyboard and mouse drivers are
installed. (These drivers are installed along with the OS.) Some OS's allow you to change the
keyboard and mouse settings. Refer to manual that comes with your OS to check that the keyboard
and mouse settings are correct.
Screen freezes, keyboard and mouse don
’
t work:
If the amount of memory is large, it takes time to copy the memory in dual mode and the system stops
working temporarily during the copying, but it is not system trouble.
Message
“
New Hardware Found
”
appears:
Such a message may appear at the system start-up or when a CPU/IO module is replaced and
incorporated into the system. This is due to the server
’
s operating specifications and does not pose any
problem.
Fail to access (read or write) to the floppy disk:
Does the floppy disk drive contain a floppy disk?
Insert a floppy disk into the floppy disk drive until it clicks.
Is the floppy disk write-protected?
Place the write-protect switch on the floppy disk to the "Write-enabled" position.
Is the floppy disk formatted?
Use a formatted floppy disk or format the floppy disk in the floppy disk drive. Refer to the manual
that comes with the OS for formatting a floppy disk.
Fail to access to the CD-ROM:
Is the CD-ROM properly set in the CD-ROM drive tray?
The tray is provided with a holder to secure the CD-ROM. Make sure that the CD-ROM is placed
properly in the holder.
Is the CD-ROM applicable to the server?
The CD-ROM for Macintosh is not available for use.
Fail to access the hard disk:
Is the hard disk applicable to the server?
Operation of any device that is not authorized by Bull is not guaranteed.
Is the hard disk properly installed?
Make sure to lock the hard disk with the lever on its handle. The hard disk is not connected to the
internal connector when it is not completely installed (see Chapter 8). When the hard disk is properly
installed, the drive power LED for the hard disk is lit while the server is powered.
Summary of Contents for Bull NovaScale R620 Series
Page 1: ...User s Guide Bull NovaScale R620...
Page 2: ......
Page 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Page 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Page 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Page 345: ...This page is deliberately left empty...
Page 346: ......