NovaScale R620 User Guide
Pins for protecting/clearing the password
Short-circuiting the two pins: Clears the password
Opening the two pins:
Protects the password (factory-set)
Pins for protecting/clearing the CMOS data
Short-circuiting the two pins: Clears the CMS data
Opening two pins:
Protects the CMOS data (factory-set)
The following describe the clearing procedure.
WARNING
Observe the following instructions to use the server safely. There are risks of
death or serious personal injury. See “PRECAUTIONS FOR SAFETY” in
Chapter 1.
Do not disassemble, repair, or alter the server.
How to Clear CMOS
1.
Power off the NovaScale/ft Server series and unplug both power cords.
2.
Remove the both CPU/IO modules (#1 and #2) from the NovaScale/ft Server series (see “Removing CPU/IO
Module” in chapter 8).
3.
Make setting of jumper switch for clearing CMOS of CPU/IO # 0.
Remove the clips from the jumper pins 11-12 and place them on the jumper pins 1-2 on the CPU/IO Module
#1.
4.
Mount only the CPU/IO Module # 0 to the NovaScale/ft Server series (see “Installing CPU/IO Module” in
chapter 8).
5.
Connect the power cord of the CPU/IO module #0 and press the POWER switch to power on.
6.
When you see “8150: NVRAM Cleared By Jumper” and “Press <F1> to resume, <F2> to Setup” during
POST after the start-up, press the POWER switch to power off, and then disconnect the power cord from the
outlet.
Example
-------------------------------------------------------------------------------------------------
Phoenix ServerBIOS 3 Release 6.0
Copyright 1985-2003 Phoenix Technologies Ltd.
All Rights Reserved
GPJ1. HA. XXXX. X. XXXXXXXXXX
IGPJ BIOS Release X. X
Build Time: XX/XX/XX XX : XX : XX
2x Intel (R) Xeon (R) CPU 3.60GHz
3072M System RAM Passed
2048K Cache SRAM Passed
System BIOS shadowed
Video BIOS shadowed
IPMI Base Board Management Controller was detected.
Device ID : XX Device Revision : XX
IPMI Version : X. X Firmware Revision : XX. XX
Self Test Result : XXXXH
SMBIOS Initialize. . . . . . . . . Passed
System Monitoring Check. Passed
ERROR
4-33
Summary of Contents for Bull NovaScale R620 Series
Page 1: ...User s Guide Bull NovaScale R620...
Page 2: ......
Page 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Page 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Page 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Page 345: ...This page is deliberately left empty...
Page 346: ......