NovaScale R620 User Guide
7-5
On-screen error message
Cause
Action
0613 COM A configuration
change
COM A configuration is faulty.
0614 COM A config, error -
device disable
Device constructing COM A is
faulty.
If restarting does not help after resetting the setting
to default by using BIOS setup, replace the CPU/IO
module.
0B28 Unsupported
Processor detected on
Processor 1
Unsupported CPU is mounted.
0B29 Unsupported
Processor detected on
Processor 2
Unsupported CPU is mounted.
Check the supported CPU and replace it. If this does
not help, replace the CPU/IO module.
0B60 DIMM group #1 has
been disabled
Replace DIMM Group#1.
0B61 DIMM group #2 has
been disabled
Replace DIMM Group#2.
0B62 DIMM group #3 has
been disabled
DIMM is faulty.
Replace DIMM Group#3.
0B70 The error occurred
during temperature
sensor reading
I2C pass is faulty.
Sensor is faulty.
Replace the part that relevant sensor is mounted.
0B71 System Temperature
out of the range
Temperature is abnormal.
Fan is abnormal.
Check if fan is faulty or clogging has occurred. If
there is no problem, replace CPU/IO module.
0B74 The error occurred
during voltage sensor
reading
I2C pass is faulty.
Sensor is faulty.
Replace the part that relevant sensor is mounted.
0B75 System voltage out of
the range
Voltage is abnormal.
If turning AC power off and on does not help, replace
the CPU/IO module.
0B80 BMC Memory Test
Failed
RMC device is faulty.
0B81 BMC Firmware Code
Area CRC check failed
Replace the CPU/IO module or ft Remote
Management Card (option).
0B82 BMC core Hardware
failure
0B83 BMC IBF or OBF
check
failed
RMC device is faulty.
Replace the CPU/IO module or ft Remote
Management Card (option).
0B8A BMC SEL area full
There is no space to write
system event logs.
Clear system event logs after saving them.
0B8B BMC progress check
timeout
BMC check is suspended.
Replace the CPU/IO module or ft Remote
Management Card (option).
0B8C BMC command
access failed
BMC command access failed. Replace the CPU/IO module or ft Remote
Management Card (option).
0B8D Could not redirect the
console - BMC Busy
Console cannot be redirected
(BMC is busy).
There is a possibility that the BMC was busy and
could not respond. Restart the server again.
0B8E Could not redirect the
console - BMC Error
BMC is faulty.
Replace the CPU/IO module or ft Remote
Management Card (option).
0B8F Could not redirect the
console
–
BMC
parameter Error -
Configuration is faulty.
Configure the console redirection by using BIOS
setup.
0B90 BMC Platform
Information Area
corrupted
0B91 BMC update firmware
corrupted
BMC device is faulty.
0B92 Internal Use Area of
BMC FRU corrupted
Data within SROM is faulty.
Replace the CPU/IO module or ft Remote
Management Card (option).
0B93 BMC SDR Repository
empty
SDR data is faulty.
If updating SDR does not help, replace the CPU/IO
module or ft Remote Management Card (option).
0B94 IPMB signal lines do
not respond
SMC is faulty.
Replace the CPU/IO module or a centre plane after
determining where IPMB error has occurred based
on OS information.
0B95 BMC FRU device
failure
NVRAM within BMC is faulty.
Replace the CPU/IO module or ft Remote
Management Card (option).
Summary of Contents for Bull NovaScale R620 Series
Page 1: ...User s Guide Bull NovaScale R620...
Page 2: ......
Page 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Page 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Page 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Page 345: ...This page is deliberately left empty...
Page 346: ......