NovaScale R620 User Guide
Procedure in the Server Maintenance Utility
Perform the procedure below before replacement of a component.
1.
Select the target component by using the Server Maintenance Utility.
2.
Check the current state of the target component with the LEDs and event log.
3.
Click the [Clear] button in [MTBF Information] of the target component.
The MTBF clearing result can be confirmed by the LEDs on the target component. The result of the MTBF
clearing operation is registered in the event log.
CHECK:
At this point, the "State" display on the target component screen is not changed.
If the MTBF clear is executed in the following conditions, diagnostics of the CPU/IO modules are
automatically performed after MTBF clear:
-
The target CPU/IO module is turned on
-
Both of the target CPU module and IO module are stopped
4.
Start the component.
CHECK:
At this point, the "State" display on the target component screen is changed.
Sample screen of Server Maintenance Utility
[PCI Module]
5-56