NovaScale R620 User Guide
7-26
Description: TraceLevel parameter not located in registry; Default trace level used is 32.
SCSI control error appears in the system event log:
This symptom occurs, for example, when a SCSI chip receives a reset request from a different SCSI
chip. The process will be continued properly by the retry function.
It is likely to occur when the server shifts from the simplex mode to the duplex mode at OS start-up or
during maintenance operations. If the number of the following errors recorded in the system event log
is few, ignore the errors.
This error is logged about 5 to 50 times in two or three minutes when the server shifts from the
simplex mode to the duplex mode during maintenance operations. Ignore these errors as well.
Source:
adpu320
Type:
Error
Event ID:
11
Description: The driver detected a controller error on \Device\Scsi\adpu320xx.
If this error is recorded many times, the hard disk drive may be faulty. Contact your service
representative.
SCSI device timeout appears in the system event log:
This symptom occurs when the processing speed of HDDs is slower than the request from the
operating system. The process will be continued properly by the retry function.
It is likely to occur when the server shifts from the simplex mode to the duplex mode at OS start-up or
during maintenance operations. If the number of the following errors recorded in the system event log
is few, ignore the errors.
This error is logged about 5 times when the server shifts from the simplex mode to the duplex mode
during maintenance operations. Ignore these errors as well.
Source:
adpu320
Type:
Error
EventID:
9
Description: The device, \Device\Scsi\adpu320xx, did not respond within the timeout period.
Source:
adpu320
Type:
Error
EventID:
117
Description: The driver for device \Device\Scsi\adpu320xx detected a port timeout due to prolonged
inactivity. All associated busses were reset in an effort to clear the condition.
If this error is recorded many times, the hard disk drive may be faulty. Contact your service
representative.
Event log which warn CPU load monitoring is registered:
If ESMPRO Agent cannot get performance information from the OS due to a temporary resource
shortage or high load ratio on the system, it will record the following event log. However, there is no
real problem on operation. (In the description, Y and X represent alphanumeric characters.)
Source:
ESMCpuPerf
Type:
Information
Event ID:
9005
Description: Cannot get system performance information now (YYYY Code=xxxx).
If ESMPRO Agent cannot get information, it will treat the load ratio as 0%. So, if ESMPRO Agent
cannot get information continuously, the CPU load ratio may appear lower than the actual value.
HAS Fault Tolerance-related logs are recorded in the system event log:
The following event logs may be recorded when the server is managed using ESMPRO Manager, but
there is no problem in continue operating the system. However, there might be a problem in OS or
software environment if logs are recorded repeatedly. Contact your maintenance service company.
Summary of Contents for Bull NovaScale R620 Series
Page 1: ...User s Guide Bull NovaScale R620...
Page 2: ......
Page 17: ...NovaScale R620 User Guide Water cooling kit 1 4...
Page 74: ...NovaScale R620 User Guide 7 Configure the mirror of the extended volume 3 15...
Page 122: ...NovaScale R620 User Guide Exit Move the cursor onto Exit to display the Exit menu 4 23...
Page 345: ...This page is deliberately left empty...
Page 346: ......