App - 35 App - 35
APPENDIXES
Availability
(
: Available,
: Not available)
Online
Number Name
Description
Master station
Local station
Offline
SW0098
(698
H
)
SW0099
(699
H
)
SW009A
(69A
H
)
SW009B
(69B
H
)
Station number
overlap status
6
Stores the overlap status when the first station number of each
module is not overlapped.
0: Normal
1: Overlap station number (first station number only)
16
15
14
13
4
3
2
1
48
47
46
45
36
35
34
33
32
31
30
29
20
19
18
17
64
63
62
61
52
51
50
49
b15
b14
b13
b12
to
b3
b2
b1
b0
SW0098
SW0099
SW009A
SW009B
Numbers 1 to 64 in the above table indicate the station numbers.
to
to
to
to
Reserved stations and any station of the number higher than the
max. are excluded.
Unable to detect station number overlapping of standby master
stations.
For the slave stations with "Auto Following" set for transmission
speed, station numbers may not be detected even when any of
them are overlapping.
SW009C
(69C
H
)
SW009D
(69D
H
)
SW009E
(69E
H
)
SW009F
(69F
H
)
Loading/parameter
consistency status
6
Stores the consistency status between the loaded station and the
parameter settings.
A matching error occurs in any of the following cases.
1) Station type mismatch
2) Number of occupied stations mismatch
3) Expanded cyclic setting mismatch
4) CC-Link compatible version mismatch
A matching error will not occur when installation parameter. (For
example, a matching error will not occur when a remote device
station is installed and the parameter setting is an intelligent
device station.)
0: Normal
1: Matching error
Example of matching error
Installation
Remote device station
Intelligent device station
Parameter
Remote I/O station
Remote I/O station
Remote device station
16
15
14
13
4
3
2
1
48
47
46
45
36
35
34
33
32
31
30
29
20
19
18
17
64
63
62
61
52
51
50
49
b15
b14
b13
b12
to
b3
b2
b1
b0
SW009C
SW009D
SW009E
SW009F
Numbers 1 to 64 in the above table indicate the station numbers.
to
to
to
to
Reserved stations and any station of the number higher than the
max. are excluded.
6: Only the bit for the first station number is turned on.
The status is checked and stored only at link startup and at parameter update.
(To the next page)
Summary of Contents for L26CPU-BT
Page 1: ......
Page 2: ......
Page 32: ...3 5 3 5 3 SPECIFICATIONS ...
Page 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Page 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Page 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Page 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Page 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Page 139: ...8 33 8 33 8 FUNCTIONS ...
Page 151: ...8 45 8 45 8 FUNCTIONS ...
Page 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Page 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Page 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Page 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Page 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Page 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Page 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Page 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Page 439: ...App 75 App 75 APPENDIXES MEMO ...
Page 447: ......
Page 448: ......
Page 449: ......