3 - 9 3 - 9
3 SPECIFICATIONS
(3) List of the "handy functions"
Item Description
Reference
Remote device station initialization
procedure registration function
Programs for the initial setting become unnecessary, since the
initial settings in the remote device station are set at the network
parameter. The initial settings in the remote device station can
be configured easily.
Section 8.3.1
Event issuance for the interrupt
program
Since the interrupt program of the programmable controller CPU
is executed according to the established event issuance
conditions, high speed data receive processing can be made
without being influenced by the sequence scan.
Section 8.3.2
Automatic CC-Link startup
The CC-Link starts automatically, only by turning the power on,
and the operation at the system construction can be checked.
Section 8.3.3
Reserved station function
By setting slave stations that will be connected in the future as
reserved stations, they will not be treated as data link faulty
stations.
Section 8.3.4
Error invalid station setting function
Prevents slave stations that may be powered off in the system
configuration from being treated as data link faulty stations by
setting the network parameters.
Section 8.3.5
Temporary error invalid station
setting function
Changes slave stations without detecting errors during online
operation.
Also, prevents slave stations, which are turned off in the system
configuration, from being treated as data link faulty stations
temporarily.
Section 8.3.6
Scan synchronous function
Selects whether to synchronize or not the link scan with
sequence scan.
In the synchronous mode, the link scan is performed
synchronously with the sequence scan. Therefore, the output
data can be sent in high speed.
In the asynchronous mode, the link scan is performed not
synchronized to the sequence scan. Therefore, a high speed link
scan can be performed independent of the sequence scan.
Section 8.3.7
Data link stop/restart
Stops or restarts the data link that is being executed.
By stopping the data link, the program debug can be performed
efficiently, since data from other stations are not received, and
data are not sent from the host station.
Section 8.3.8
Remote I/O station points setting
Allows the I/O points of the remote I/O stations to be selected
from among 8 points, 16 points and 32 points, reducing the
number of reserved points.
The refresh device points of the programmable controller CPU
and the link refresh time can be saved.
Section 8.3.9
Master station duplication error
cancel function
Master station duplication errors can be canceled without turning
the power supply off to on, or without resetting the
programmable controller CPU.
Section 8.3.10
Transmission speed auto following
setting
When the host station is a local station or a standby master
station, an auto following occurs according to the transmission
speed of the master station, what eliminates setting errors of the
transmission speed.
Section 7.2 (2)
Status logging
Logs the data link status of all stations.
When multiple stations repeat normal/faulty, or when determined
stations and later repeat normal/faulty, this function enables
easy identification of the causes, such as contact failure of the
cable, or the noise occurrence location.
Section 15.4.3
Summary of Contents for L26CPU-BT
Page 1: ......
Page 2: ......
Page 32: ...3 5 3 5 3 SPECIFICATIONS ...
Page 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Page 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Page 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Page 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Page 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Page 139: ...8 33 8 33 8 FUNCTIONS ...
Page 151: ...8 45 8 45 8 FUNCTIONS ...
Page 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Page 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Page 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Page 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Page 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Page 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Page 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Page 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Page 439: ...App 75 App 75 APPENDIXES MEMO ...
Page 447: ......
Page 448: ......
Page 449: ......