App - 5 App - 5
APPENDIXES
Address
Hex. Dec.
Item Description
D4
H
to D7
H
212 to 215
16-point remote
I/O station setting
Stores the station numbers of the remote I/O stations set as 16
points in the remote I/O station points setting.
1,
2
Default value: 0 (no setting)
Storage area: Bit corresponding to the station number turns on.
D8
H
to DB
H
216 to 219
0 points reserved
station setting
Stores the station numbers of the reserved stations set to 0 points.
1
Default value: 0 (no setting)
Storage area: Bit corresponding to the station number turns on.
DC
H
to DF
H
220 to 223
(Use prohibited)
—
1 Used in the remote net ver.2 mode or remote net additional mode.
2 When the setting is "8 8 Points (Reserved)", the station numbers are stored into both the 8-
point remote I/O station setting and 16-point remote I/O station setting.
(2) Remote input (RX) and remote output (RY)
Used when the remote net ver.1 mode or remote net additional mode is selected.
(a) Master station remote I/O station/remote device station/local station
1) Master station
The input status from the remote I/O station, remote device station
(RX) and local station (RY) is stored.
Two words are used per station.
2) Local station
Data to be sent to the master station is stored in the remote output
(RY) of the address corresponding to the host station number.
The input status from the remote I/O station, remote device station
(RX) and other local station is stored.
Two words are used per station.
E0
H
RX F to RX 0
E1
H
E2
H
E3
H
E4
H
E5
H
E6
H
E7
H
E8
H
E9
H
15C
H
RX 1F to RX 10
RX 2F to RX 20
RX 3F to RX 30
RX 4F to RX 40
RX 5F to RX 50
RX 6F to RX 60
RX 7F to RX 70
RX 8F to RX 80
RX 9D to RX 90
RX7CF to RX7C0
RX7DF to RX7D0
RX7EF to RX7E0
RX7FF to RX7F0
Address
Remote input (RX)
X0F to X00
X1F to X10
Master station
Remote I/O station
(Station number 1: occupies 1 station)
160
H
161
H
162
H
163
H
164
H
165
H
166
H
167
H
168
H
169
H
1DC
H
1DD
H
1DE
H
1DF
H
Address
RY F to RY 0
RY 1F to RY 10
RY 2F to RY 20
RY 3F to RY 30
RY 4F to RY 40
RY 5F to RY 50
RY 6F to RY 60
RY 7F to RY 70
RY 8F to RY 80
RY 9D to RY 90
RY7CF to RY7C0
RY7DF to RY7D0
RY7EF to RY7E0
RY7FF to RY7F0
Remote output (RY)
Local station
(Station number 2: occupies 4 stations)
15D
H
15E
H
15F
H
For station
number 1
… The last two bits cannot be used for communication between the master
station and the local station.
(In the example below, RY9E and RY9F cannot be used.)
For station
number 2
For station
number 3
For station
number 4
For station
number 5
For station
number 63
For station
number 64
to
to
to
to
For station
number 1
For station
number 2
For station
number 3
For station
number 4
For station
number 5
For station
number 63
For station
number 64
Summary of Contents for L26CPU-BT
Page 1: ......
Page 2: ......
Page 32: ...3 5 3 5 3 SPECIFICATIONS ...
Page 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Page 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Page 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Page 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Page 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Page 139: ...8 33 8 33 8 FUNCTIONS ...
Page 151: ...8 45 8 45 8 FUNCTIONS ...
Page 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Page 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Page 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Page 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Page 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Page 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Page 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Page 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Page 439: ...App 75 App 75 APPENDIXES MEMO ...
Page 447: ......
Page 448: ......
Page 449: ......