App - 23 App - 23
APPENDIXES
Availability
(
: Available,
: Not available)
Online
Number Name
Description
Master station
Local station
Offline
SB0008
(5E0
H
, b8)
Loop test request
Executes loop tests for the stations specified by SW0008.
OFF: Not requested
ON : Requested
SB0009
(5E0
H
, b9)
Parameter information
read request
Reads the parameter setting information for the actual system
configuration.
(enabled only on Ver.1 remote stations)
OFF: Not requested
ON : Requested
SB000B
(5E0
H
, b11)
Transmission speed
test request
Use this to perform the transmission speed test.
OFF: Not requested
ON : Requested
SB000C
(5E0
H
, b12)
Forced master
switching
Forcefully transfers the data link control from the standby master
station that is controlling the data link to the standby master station in
case the standby master station becomes faulty.
OFF: Not requested
ON : Requested
1
SB000D
(5E0
H
, b13)
Remote device station
initialization procedure
registration instruction
Starts the initial processing using the information registered during the
initialization procedure registration.
While SB000D is on, the refresh of the remote input/output and
remote registers stops.
OFF: Not instructed
ON : Instructed
3
SB0020
(5E2
H
, b0)
Module status
Indicates the module access (module operation) status.
OFF: Normal (Module is operating normally)
ON : Abnormal (Module error has occurred)
SB0040
(5E4
H
, b0)
Data link restart
acceptance
Indicates the data link restart instruction acknowledgement status.
OFF: Not acknowledged
ON : Startup instruction acknowledged
SB0041
(5E4
H
, b1)
Data link restart
complete
Indicates the data link restart instruction acknowledgement
completion status.
OFF: Not complete
ON : Startup complete
SB0042
(5E4
H
, b2)
Refresh instruction
acknowledgement
status at standby
master switching
Indicates whether or not the refresh instruction at standby master
switching have been acknowledged.
OFF: Not executed
ON : Instruction acknowledged
SB0043
(5E4
H
, b3)
Refresh instruction
complete status at
standby master
switching
Indicates whether or not the refresh instruction at standby master
switching is complete.
OFF: Not executed
ON : Switching complete
SB0044
(5E4
H
, b4)
Data link stop
acceptance
Indicates the data link stop instruction acknowledgement status.
OFF: Not acknowledged
ON : Stop instruction acknowledged
SB0045
(5E4
H
, b5)
Data link stop
complete
Indicates the data link stop instruction acknowledgement completion
status.
OFF: Not complete
ON : Stop complete
SB0046
(5E4
H
, b6)
Forced master
switching
executable status
Indicates whether the forced master switching (SB000C) signal can
be executed or not.
OFF: Cannot be executed.
ON: Can be executed.
1
SB0048
(5E4
H
, b8)
Temporary error
invalid acceptance
status
Indicates the acknowledgement status of remote station temporary
error invalid instruction.
OFF: Not executed
ON : Instruction acknowledged
SB0049
(5E4
H
, b9)
Temporary error
invalid complete
status
Indicates the acknowledgement completion status of remote station
temporary error invalid instruction.
OFF: Not executed
ON : Temporary error invalid station established/Specified station
number is invalid
1: Can be used for the standby master station only.
3: Parameter setting is required in the case of a standby master station.
(To the next page)
Summary of Contents for L26CPU-BT
Page 1: ......
Page 2: ......
Page 32: ...3 5 3 5 3 SPECIFICATIONS ...
Page 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Page 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Page 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Page 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Page 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Page 139: ...8 33 8 33 8 FUNCTIONS ...
Page 151: ...8 45 8 45 8 FUNCTIONS ...
Page 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Page 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Page 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Page 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Page 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Page 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Page 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Page 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Page 439: ...App 75 App 75 APPENDIXES MEMO ...
Page 447: ......
Page 448: ......
Page 449: ......