App - 26 App - 26
APPENDIXES
Availability
(
: Available,
: Not available)
Online
Number Name
Description
Master station
Local station
Offline
SB0076
(5E7
H
, b6)
Temporary error
invalid station setting
information
Indicates whether there is a temporary error invalid station setting.
OFF: No setting
ON : Setting exists (information is stored in SW007C to SW007F)
SB0077
(5E7
H
, b7)
Parameter receive
status
Indicates the parameter receive status from the master station.
OFF: Reception complete
ON : Reception not complete
SB0078
(5E7
H
, b8)
Host station switch
change detection
Detects changes to the host setting switch during data linking.
OFF: No changes detected
ON : Changes detected
SB0079
(5E7
H
, b9)
Master station return
specification
information
Indicates whether the "Type" setting of the network parameters is set
to "Master station" or "Master station (Duplex function)."
OFF: Master station
ON : Master station (Duplex function)
SB007B
(5E7
H
, b11)
Host master/standby
master operation
status
Indicates whether the host operates as the master or standby master
station.
OFF: Operates as the master station (controlling data link)
ON : Operates as the standby master station (standby)
SB007C
(5E7
H
, b12)
Slave station
refresh/compulsory
clear setting status in
case of programmable
controller CPU STOP
Indicates the parameter-set slave station refresh/compulsory clear
setting status in case of programmable controller CPU STOP.
OFF: Refresh
ON : Clears compulsorily
SB0080
(5E8
H
, b0)
Other station data link
status
2
Indicates the communication status with the slave stations.
OFF: All stations normal
ON : Faulty station exists (information is stored in SW0080 to
SW0083)
SB0081
(5E8
H
, b1)
Other station
watchdog timer error
status
Indicates the occurrence of a watchdog timer error in other stations.
OFF: No error
ON : Error occurrence.
SB0082
(5E8
H
, b2)
Other station fuse
blown status
Indicates the fuse blown occurrence status at other stations.
(SW0088 to SW008B)
OFF: No error
ON : Error occurrence.
SB0083
(5E8
H
, b3)
Other station switch
change status
Detects changes in setting switches of other stations during data
linking.
OFF: No change
ON : Change detected.
SB0090
(5E9
H
, b0)
Host line status
Indicates the line status of the host.
OFF: Normal
ON : Abnormal (line disconnection)
SB0094
(5E9
H
, b4)
Other stations
transient transmission
status
Indicates whether a transient transmission error has occurred in other
stations.
OFF: No error
ON : Error occurrence. (SW0094 to SW0097)
Even when a dedicated instruction was retried, an error is detected.
SB0095
(5E9
H
, b5)
Master station
transient transmission
status
Indicates the transient transmission status of the master station.
OFF: Normal
ON : Abnormal
SB00B4
(5EB
H
, b4)
Standby master
station test result
Stores the test result of loop test 1.
OFF: Normal
ON : Abnormal
2: The other station data link status (SB0080) takes up to 6 seconds to turn on after a slave station connected
to the master/local station becomes faulty.
The time to turn ON differs according to the system configuration, faulty status or other conditions.
(To the next page)
Summary of Contents for L26CPU-BT
Page 1: ......
Page 2: ......
Page 32: ...3 5 3 5 3 SPECIFICATIONS ...
Page 51: ...4 2 4 2 4 PROCEDURE BEFORE OPERATION 4 ...
Page 61: ...6 4 6 4 6 INSTALLATION AND CONNECTION ...
Page 63: ...6 6 6 6 6 INSTALLATION AND CONNECTION 8 The connection method is shown below ...
Page 70: ...6 13 6 13 6 INSTALLATION AND CONNECTION ...
Page 72: ...6 15 6 15 6 INSTALLATION AND CONNECTION ...
Page 139: ...8 33 8 33 8 FUNCTIONS ...
Page 151: ...8 45 8 45 8 FUNCTIONS ...
Page 246: ...11 9 11 9 11 EXAMPLE OF COMMUNICATION BETWEEN THE MASTER STATION AND REMOTE DEVICE STATIONS ...
Page 311: ...13 2 13 2 13 COMMUNICATION BETWEEN THE MASTER STATION AND INTELLIGENT DEVICE STATIONS MEMO 13 ...
Page 321: ...14 10 14 10 14 EXAMPLE OF COMMUNICATION WHEN MOUNTING MODULES ON THE HEAD MODULE ...
Page 326: ...15 5 15 5 15 TROUBLESHOOTING To the next page ...
Page 327: ...15 6 15 6 15 TROUBLESHOOTING To the next page ...
Page 328: ...15 7 15 7 15 TROUBLESHOOTING ...
Page 329: ...15 8 15 8 15 TROUBLESHOOTING 2 Troubleshooting by status logging ...
Page 436: ...App 72 App 72 APPENDIXES 7 Operating procedure of the transmission speed test ...
Page 439: ...App 75 App 75 APPENDIXES MEMO ...
Page 447: ......
Page 448: ......
Page 449: ......