3-31
© Copyright 2006 Microwave Data Systems Inc. All Rights Reserved
User Interface Manual
MDS FIVE Series
05-4574A01, Rev. C
3. Select and modify desired parameters.
4. Click the “Update” to button submit these changes.
5. Click the “Reset” button to undo changes
3.3.14.3 CLI Configuration
1. Navigate to Administration
Æ
Security Configuration
2. All Security related parameters are displayed with current/present values.
3. To edit an individual parameter, enter its hotkey, edit its value and press
the Enter key.
4. To revert to the previous value, press the “Esc” key while editing the value.
5. Scroll through the options for the following parameters using the Space
Bar key and press the Enter key to select among the options.
a. Command Line Interface
b. HTTP Access
6. To update the edited parameter, press the hotkey for “Update”.
7. The page is refreshed and displayed with the updated or current/present
values.
8. If parameters are not updated with entered values, the value entered may
be invalid for that parameter.
3.3.14.4 SNMP Configuration
1. Select a parameter from the MIB section ccmSDIDUSysCfgSecurity
2. Use the SNMP GET command to get the value of the required parameter
3. Use the SNMP SET command to set the value of the required parameter
4. The SNMP agent will return the actual value upon successful set or get
operation. Upon failure, the SNMP agent will return an error if the value set
is out of range, or the agent is not able to get or set the value, or the user
does not have access rights to the selected parameter.