3-51
© Copyright 2006 Microwave Data Systems Inc. All Rights Reserved
User Interface Manual
MDS FIVE Series
05-4574A01, Rev. C
The screen shown in Figure 3-33 enables the user to configure the following STM-
1 channel related parameters.
1.
Channel Selection check box
– To select STM-1 Channel(s).
2.
Loop back
– To select Loop back (Normal, Local, Remote).
3.3.26.2 WEB Configuration
1. Navigate to Link Configuration
Æ
Data Link and click on the “STM1/OC3
Ports” link in the left panel.
2. All configured channels will be displayed with their current settings.
3. To configure channel(s), check the checkbox(es) next to that channel
number(s).
4. Change the required parameters under “New settings” and click the
“update” button.
3.3.26.3 CLI Configuration
Figure 3-34. STM1/OC3 Configuration
1. Navigate to IDU Configuration
Æ
Data Link Configuration
Æ
STM1/OC3
Configuration.
2. All STM-1 parameters are displayed with current/present values (see
3. To revert to the previous value, press the “Esc” key while editing the value.
4. Scroll through the options of all the STM-1 parameters using the Space
Bar key and press the Enter key to select among the options.
5. The page is refreshed and displayed with the updated or current/present
values.