3.3.32.3 CLI Configuration
1. Navigate to IDU Configuration
Æ
Radio Link
Æ
Radio Wizard
Æ
ODU
opmode Screen
2. Select ODU op-mode using the Space Bar key and press the Enter key.
Then press the hotkey to switch to the Framer IDU operation mode
Selection Screen.
3. Select IDU op-mode using the Space Bar key and press the Enter key. In
the case of East-West mode, two independent IDU op-modes can be
selected.
4. Select the ODU type, Polarization and Alignment Mode using the Space
Bar key and press the Enter key. Enter the Starting TX Power. Then, press
the hotkey to switch to ODU East Channel Selection Screen
5. Select ODU East Channel Number using the Space Bar key and press the
Enter key. Then, press the hotkey to switch to the Reconfigure Framer
Screen
6. If the ODU Opmode is East-West, then the user can select the ODU West
channel number by switching to the ODU West Channel Selection Screen.
7. The selected parameters will be displayed in the summary page. Verify all
values. To update, press the hotkey for “Update IDU Config Params”. To
reconfigure, press the hotkey for “Radio Wizard – ODU opmode
Selection”.
3.3.32.4 SNMP Configuration
1. Select a parameter from the MIB section ccmSDIDULinkCfgRadioLink
2. Use the SNMP GET command to get the value of the required parameter
3. Use the SNMP SET command to set the value of the required parameter
4. The SNMP agent will return the actual value upon successful set or get
operation. Upon failure, the SNMP agent will return an error if the value set
is out of range, or the agent is not able to get or set the value, or the user
does not have access rights to the selected parameter
Warning
To configure the Framer and ODU related parameters, a standard
IO card and modem should be configured and present. Otherwise
an error message will be displayed.
Note
If the selected parameters in the current screen are not supported
by the system, an error message will be displayed on the next
page. Go back to the previous screen by pressing the Esc key and
select a suitable value for that parameter
.