10. ODU channel number
3.3.29 Tx Mute Configuration
User Access Level: Level 3
Figure 3-37. ODU Tx mute
3.3.29.1 Description
This screen enables the user to configure the ODU Tx mute parameter (see
Figure 3-37). This page will not be available in the case of protected (1+1)
operation.
3.3.29.2 WEB Configuration
1. Navigate to Link Configuration
Æ
Radio Link and click on the “ODU Tx Mute
Configuration” link in the left panel
2. Click on the radio button to select the required option and click the
“update” button.
3.3.29.3 SNMP Configuration
1. Select a parameter from the MIB section
ccmSDIDULinkCfgRadioLinkProtection->
ccmSDIDURadioLinkProtTxMuteCfg.
2. Use the SNMP GET command to get the value of the required parameter.
3. Use the SNMP SET command to set the value of the required parameter.
4. The SNMP agent will return the actual value upon successful set or get
operation. Upon failure, the SNMP agent will return an error if the value set