ODU Fault
Upper
ODU
The ODU has indicated a
fault condition or
unsolicited message, if
supported. Fault
detection via polling of
ODU. Polling interval 5
sec. Polling done via API
function call. Report of
this alarm in the GUI/
Syslog/Alarm history
shall indicate the fault
code from the ODU.
N/A
73
Critical
ODU Comm
Failure
Upper
ODU
The IDU is unable to
communicate with the
ODU. This could be a
problem with the ODU or
a problem with the cable
connecting the ODU to
the IDU.
N/A
74
Critical
Protection
Switch
MODEM/
ODU
This alarm shall be set
when an AL1 command
is received from the
active MODEM/ODU,
then cleared when an
AL2 command is
received from the
standby MODEM/ODU.
Report of this alarm in the
GUI/Syslog/Alarm history
shall indicate the fault
code from the ODU, if
received.
N/A
75
Major
East ATPC
Tx at Max
Power
ODU
The IDU is unable to
increase the Tx Power as
requested by link partner
due to maximum power
being reached. Maximum
power is specified in the
configuration table.
N/A
76
Info
Table 6-1
Alarm
Affected
Component
Description
LED to RED
Alarm
Code
Severity