User Interface Manual
© Copyright 2006 Microwave Data Systems Inc. All Rights Reserved
3-44
MDS FIVE Series
05-4574A01, Rev. C
3.3.23.1 Description
This screen enables the user to configure the following E1 / T1 channel related
parameters (see Figure 3-28).
1.
Channel section Checkbox
– To select channel(s) to apply
configurations.
2.
Encoding
– To select encoding for selected E1 / T1 channel.
3.
TX Data
– To select TX data for selected E1 / T1 channel.
4.
Loop back
– To select Loop back for selected E1 / T1 channel.
5.
LOS Action
– To select LOS Action for selected E1 / T1 channel. “Auto
transmit all ones” will be selectable only if TX Data is “All ones”.
6.
AIS type
– To select AIS type for selected E1 / T1 channel. Depending on
the channel type (E1 / T1) configuration, the choices displayed will differ.
7.
Build out
– To select Build out for selected E1 / T1 channel. Depending
on the channel type (E1 / T1) configuration, the choices displayed will
differ.
3.3.23.2 WEB Configuration
1. Navigate to Link Configuration
Æ
Data Link and click on the “E1/T1 Ports”
link in the left panel.
2. All configured channels will be displayed with their current configurations
in the form of table.
3. To configure channel(s), click on that channel’s checkbox.
4. Change the required parameters under “new settings” and click “update”
button.
3.3.23.3 CLI Configuration
The CLI uses two screens to configure the E1 /T1 channel related parameters.