3-71
© Copyright 2006 Microwave Data Systems Inc. All Rights Reserved
User Interface Manual
MDS FIVE Series
05-4574A01, Rev. C
3.3.37.2 WEB Configuration
1. Navigate to Analysis and click on the “alarm” link in the left panel.
2. Now click on the “Discrete” link.
3. All alarm attributes will be displayed with current/present values.
4. Change the required parameters and click the “Update” button.
5. The page will be refreshed and displayed with current/present values.
6. All the checkboxes for E-mail notification may be selected by pressing the
button “Check All Mails”.
7. All the checkboxes for E-mail notification may be deselected by pressing
the button “Clear All Mails”.
8. All the checkboxes for masking the alarms may be selected by pressing
the button “Check All Masks”.
9. All the masks may be deselected by pressing the button “Clear All Masks”.
10. If an alarm is active (set), the description of that alarm will be red in color.
3.3.37.3 SNMP Configuration
1. Select a parameter from the MIB section ccmSDIDUAnalysisAlarm, under
ccmSDIDUAnalysis group
2. Use the SNMP GET command to get the value of the required parameter
3. Use the SNMP SET command to set the value of the required parameter
4. The SNMP agent will return the actual value upon successful set or get
operation. Upon failure, the SNMP agent will return an error if the value set
is out of range, or the agent is not able to get or set the value, or the user
does not have access rights to the selected parameter
Use MIB objects ccmSDIDUAlarmMask and ccmSDIDUAlarmEmailMask for
accessing alarm and E-mail masks respectively. Alarm masks will be in the
following format
1=U:2=U:1=U:3=U:4=U:5=U:6=U:7=U:8=U:9=U:10=U:11=U:
use “M” to mask the alarm and “U” to unmask the alarm.