3-65
© Copyright 2006 Microwave Data Systems Inc. All Rights Reserved
User Interface Manual
MDS FIVE Series
05-4574A01, Rev. C
3.3.34.4 SNMP Configuration
1. Select a parameter from the MIB section
ccmSDIDULinkCfgRadioLinkEastODUCfg
2. Use the SNMP GET command to get the value of the required parameter
3. Use the SNMP SET command to set the value of the required parameter
4. The SNMP agent will return the actual value upon successful set or get
operation. Upon failure, the SNMP agent will return an error if the value set
is out of range, or the agent is not able to get or set the value, or the user
does not have access rights to the selected parameter.
Details of the ODU configuration are given below
1. GET the “ccmSDIDULinkUtilODUTypeCapability”,
2. Select ODU type gotten above into MIB variables
“ccmSDIDURadioEastODUCfgType
3. GET the “ccmSDIDULinkUtilEastODUChList” MIB variables value
4. SET the channel frequency gotten above into the
“ccmSDIDURadioEastODUCfgChFreq”.
5. update the ODU configuration by setting the MIB
“ccmSDIDURadioEastODUCfgChFreqReconfigure”.
Note
If the selected parameters in the current screen are not supported
by the system, an error message will be displayed on the next
page. Go back to the previous screen by pressing the Esc key and
select a suitable value for that parameter
.