3-69
© Copyright 2006 Microwave Data Systems Inc. All Rights Reserved
User Interface Manual
MDS FIVE Series
05-4574A01, Rev. C
2. Now click on the “Threshold” link.
3. The alarm threshold parameters will be displayed with current/present
values.
4. Change the required parameters and click the “Update” button.
5. The page will be refreshed and displayed with updated values.
6. If parameters are not updated with entered values, the value entered may
be invalid for that parameter.
7. Based on the “External Alarm signal level” radio button selection, the
External alarm input jumper positions will be displayed.
3.3.36.3 SNMP Configuration
1. Select a parameter from the MIB section
ccmSDIDUAnalysisAlarmThreshold
2. Use the SNMP GET command to get the value of the required parameter
3. Use the SNMP SET command to set the value of the required parameter
4. The SNMP agent will return the actual value upon successful set or get
operation. Upon failure, the SNMP agent will return an error if the value set
is out of range, or the agent is not able to get or set the value, or the user
does not have access rights to the selected parameter