MDS FIVE Series
05-4574A01, Rev. C
4. The SNMP agent will return the actual value upon successful set or get
operation. Upon failure, the SNMP agent will return an error if the value set
is out of range, or the agent is not able to get or set the value, or the user
does not have access rights to the selected parameter.
3.3.49 Loopback
User Access Level: Level 2
Figure 3-55. Loopback
3.3.49.1 Description
This screen enables the user to start or stop Loop Back (see Figure 3-55). Not all
ODUs support ODU loopback.
3.3.49.2 WEB Configuration
1. Navigate to Analysis
Æ
Loopback.
2. Select the type of loopback (Local LIU, Local Modem, Local ODU or
Remote LIU).
3. If Local or Remote LIU is selected then select the LIU type from the drop
down option.
4. Select the duration of the loopback.
5. Press the start Button to start loopback.
6. If loopback is running, press the stop button to stop it.
3.3.49.3 CLI Configuration
1. Navigate to Analysis
Æ
LoopBack.