3-21
© Copyright 2006 Microwave Data Systems Inc. All Rights Reserved
User Interface Manual
MDS FIVE Series
05-4574A01, Rev. C
3.3.7.3 CLI Configuration
1. Navigate to Administration
Æ
Network Configuration
Æ
STP
Configuration
Æ
Data Switch Configuration.
2. All STP Data parameters (STP Status and Bridge Priority) are displayed
with current/present values.
3. To edit an individual parameter, enter its hotkey, modify its value by
scrolling through the options using the Space Bar key.
4. To revert to the previous value, press the “Esc” key while editing the
value.
5. To update the edited parameter, press the hotkey for “Update”.
6. The page is refreshed and displayed with the updated or current/present
values.
3.3.7.4 SNMP Configuration
1. Select a parameter from the MIB section
ccmSDIDUSysCfgNetworkSTPData.
2. Use the SNMP GET command to get the value of the required parameter.
3. Use the SNMP SET command to set the value of the required parameter.
4. The SNMP agent will return the actual value upon successful set or get
operation. Upon failure, the SNMP agent will return an error if the value set
is out of range, or the agent is not able to get or set the value, or the user
does not have access rights to the selected parameter
3.3.8 STP NMS Configuration
User Access Level: Level 3
Figure 3-12. STP NMS Configuration.