6-19
© Copyright 2006 Microwave Data Systems Inc. All Rights Reserved
User Interface Manual
MDS FIVE Series
05-4574A01, Rev. C
STM LP-
BIP2 lkm
IDU
The SDH/SONET Mux/
Demux LP number ‘x’ has
a CRC Error. Fault
detection via polling of
LP_BIP2_T bit in STM-1
Core. Where ‘lkm’ is the
LP index as LKM
numbering. Alternate
detection via Interrupt
enabled in STM-1 core.
N/A
Solid
Major
SDIDU
Power-Up
IDU
During power-up raise
then lower this alarm.
N/A
Solid
Info
SDIDU Re-
boot
IDU
When a user reboots the
SDIDU, raise then lower
this alarm prior to re-
booting.
N/A
Solid
Info
NTP
Update
IDU
When the system time is
updated via NTP raise
then lower this alarm.
The previous system time
and new system time
should be noted in the
alarm log, snmp trap, and
syslog messages.
N/A
Solid
Info
Remote
Reconfigura
tion Failure
IDU
When a remote
reconfiguration fails and
the original configuration
is restored after timeout,
raise then lower this
alarm.
N/A
Solid
Info
FPGA
Programmin
g Failure
IDU
When the FPGA
programming fails, this
alarm shall be set.
N/A
Solid
Critical
Table 6-1
Alarm
Affected
Component
Description
LED to RED
Alarm
Code
Severity