3-57
© Copyright 2006 Microwave Data Systems Inc. All Rights Reserved
User Interface Manual
MDS FIVE Series
05-4574A01, Rev. C
3. To change RSL Low Threshold, RSL High Threshold, RSL Maximum
Threshold, CER Threshold, Tx Power Minimum, and Tx Power Maximum
values or Step size, enter required value in the text box (for Step Size
scroll through the select box) and click “update” button.
4. To Enable/Disable “Update Far End Thresholds” parameter, select the
required radio button and press “Update” button.
3.3.30.3 SNMP Configuration
1. Select a parameter from the MIB section
ccmSDIDULinkCfgRadioLinkAPC
2. Use the SNMP GET command to get the value of the required parameter.
3. Use the SNMP GET command to set the value of the required parameter.
4. The SNMP agent will return the actual value upon successful set or get
operation. Upon failure, the SNMP agent will return an error if value is set
our of range, or the agent is not able to get or set the value or the user
does not have access rights to the selected parameter.