3-85
© Copyright 2006 Microwave Data Systems Inc. All Rights Reserved
User Interface Manual
MDS FIVE Series
05-4574A01, Rev. C
2. Select the type of loopback (Local LIU, Local Modem, Local ODU or
Remote LIU) by pressing appropriate hotkey and the space bar.
3. If Local or Remote LIU is selected then select the LIU type.
4. Select the duration of the loopback by pressing appropriate hotkey and the
space bar.
5. To start loopback, press the hotkey for Start.
6. To revert to the previous value, press the “Esc” key while editing the value
7. If loopback is running, press the hotkey for stop to stop it.
3.3.49.4 SNMP Configuration
1. Select a parameter from the MIB section c ccmSDIDUAnalysisLoopback
2. Use the SNMP GET command to get the value of the required parameter
3. Use the SNMP SET command to set the value of the required parameter
4. The SNMP agent will return the actual value upon successful set or get
operation. Upon failure, the SNMP agent will return an error if the value set
is out of range, or the agent is not able to get or set the value, or the user
does not have access rights to the selected parameter.
3.3.50 Modem Temperature
3.3.50.1 SNMP Configuration
1. Select a parameter (ccmSDIDUModemEastTemperature or
ccmSDIDUModem West Temperature) from the MIB section
ccmSDIDUAnalysisModemConfig
2. Use the SNMP GET command to get the value of the required parameter
3. The SNMP agent will return the actual value upon successful set or get
operation. Upon failure, the SNMP agent will return an error the agent is
not able to get or set the value, or the user does not have access rights to
the selected parameter.