6-9
© Copyright 2006 Microwave Data Systems Inc. All Rights Reserved
User Interface Manual
MDS FIVE Series
05-4574A01, Rev. C
T1/E1 Test
Mode
StdIO
The user has selected a
T1/E1 test mode
(loopback or Tx Data).
This alarm shall be set
when the user sets the
testmode for any of the
T1/E1 channels, and
cleared when all T1/E1
channels are not in
loopback and Tx Data is
normal.
N/A
59
Info
BERT/LB/
CW Test
Mode
StdIO
This alarm shall be set
when the user enables
either BERT,, Loopback,
or CW mode, and cleared
when all BERT,
Loopback and CW
modes are disabled.
N/A
69
Info
ODU Fault
Lower
ODU
The ODU has indicated a
fault condition. Fault
detection via polling of
ODU or unsolicited
message, if supported.
Polling interval 5 sec.
Polling done via API
functional call. Report of
this alarm in the GUI/
Syslog/Alarm history
shall indicate the fault
code from the ODU.
N/A
71
Critical
ODU Comm
Failure
Lower
ODU
The IDU is unable to
communicate with the
ODU. This could be a
problem with the ODU or
a problem with the cable
connecting the ODU to
the IDU.
N/A
72
Critical
Table 6-1
Alarm
Affected
Component
Description
LED to RED
Alarm
Code
Severity