User Interface Manual
© Copyright 2006 Microwave Data Systems Inc. All Rights Reserved
3-28
MDS FIVE Series
05-4574A01, Rev. C
1.
SNTP Server Enable
– Enable / Disable SNTP Client.
2.
SNTP Server Address
– Specify SNTP Server Address.
3.
Time Zone
– Specify time difference from GMT.
4.
Date Format
– Specify desired date format (US, European, Generic)
5.
Date
– Set current terminal date.
6.
Time
– Set current terminal time.
3.3.12.2 WEB Configuration
1. Navigate to Administration
Æ
Device Configuration and click on the “Set
Time and Date” link in the left panel.
2. The current values of parameters are displayed here.
3. Select and modify desired parameters.
4. Click the “Update” to button submit these changes.
5. Click the “Reset” button to undo changes
3.3.12.3 CLI Configuration
1. Navigate to Administration
Æ
Device Configuration
Æ
Date and Time
2. All Date and time related parameters are displayed with current/present
values.
3. To edit an individual parameter, enter its hotkey, edit its value and press
the Enter key.
4. To revert to the previous value, press the “Esc” key while editing the value.
5. Scroll through the options for the following parameters using the Space
Bar key and press the Enter key to select among the options.
a. Date Format
b. SNTP Server Enable
6. To update the edited parameter, press the hotkey for “Update”.
7. The page is refreshed and displayed with the updated or current/present
values.
8. If parameters are not updated with entered values, the value entered may
be invalid for that parameter.
3.3.12.4 SNMP Configuration
1. Select a parameter from the MIB section
ccmSDIDUSysCfgDevInfoDateTime
2. Use the SNMP GET command to get the value of the required parameter
3. Use the SNMP SET command to set the value of the required parameter
4. The SNMP agent will return the actual value upon successful set or get
operation. Upon failure, the SNMP agent will return an error if the value set