3.3.35 ODU Configuration
User Access Level: Level 3
Figure 3-43. ODU Configuration
3.3.35.1 Description
This screen enables the user to configure the ODU and is shown in Figure 3-43.
The spiral search function is not generally used for operation links. The function is
included to allow for carrier searches when oscillators are far off in frequency or
for testing ODU performance.
3.3.35.2 WEB Configuration
1. Click on the radio button to select the ODU (East/West).
2. Press the Disable, Enable, Mute, or Unmute button.
3. In the case of Protected mode, the mute and unmute options will not be
available.
4. Click on the radio button to Enable or Disable Spiral Search. For general
operation, this option should be disabled.
5. The Spiral Search Window value can be entered in the text box and it
should be within the range specified.
6. Press the Update button to update the Spiral Search Values.