Equalizer Taps and Constellations are plotted as shown in Figure 3-49 and Figure
3-50.
3.3.40.2 WEB Configuration
1. Navigate to Analysis and click on the “Graphs” link in the left panel.
2. Based on the ODU operation mode configuration, the number of graphs
displayed will differ. For example, if the ODU operation is East-West, all 8
parameters’ graphs will be accessible. If the ODU operation mode is not
East-West, only 4 (either East or West) graphs will be accessible.
3. Select any one link to view the graph of that parameter.
4. The X-axis time range can be selected. (From 1,2,4,12 or 24). If 1 hour is
selected, it will plot the graph using last hour of data.
5. When the mouse is moved over the graph area, the corresponding value
at the mouse point will be displayed under the graph area. This enables
the user to easily read X and Y values.
3.3.40.3 SNMP Configuration
From SNMP manager graph data can be obtained by reading a MIB object
ccmSDIDUAnalysisPerfData from the ccmSDIDUAnalysis section.