57
KATANA S610M Inverter Specialized for Elevator Manual
5: Inverter ready to operate (RDY)
When this output signal is effective, it means the inverter has no errors, bus voltage is normal and inverter operation enable
ineffective. So the inverter is ready to receive starting command.
6: Stopping the inverter caused by under-voltage (LU)
When DC bus voltage is lower than undervoltage limit, the terminal outputs indicating signal and LED displays “P.oFF”.
7: Inverter failure
When the inverter is in failure, the terminal outputs indicating signal.
8: Up signal output
When the elevator is going up, the terminal outputs indicating signal.
9: Down signal output
When the elevator is going down, the terminal outputs indicating signal.
10: Inverter operating at zero speed
When the inverter is operating at zero speed, the terminal outputs indicating signal. To be specific, under V/F control, when
output frequency is 0, it outputs indicating signal; under non V/F control, when feedback frequency is smaller than the
corresponding frequency of F11.10, it outputs indicating signal.
11: Braking control output
This terminal is for controlling the on/off of braking.
12: Operating contactor control output
This terminal is for controlling the on/off of operating contactor.
13: Signal of Motor enables to open the brake.
When this signal is available, inform microcontrol board enable to open the brake.
14: Direction signal with light-load
0: Upward direction is light-load; 1: Downward direction is light-load.
15: Pre-open door signal
When this signal output is available during operation, inform microcontrol board enable to pre-open the door.
16: Braking power output
To control the controlling force of the braking power.
17: Output of basic pole block error (E030)
It will output for indication if inverter appears basic pole block error (E030).
18: Inverter is ready ( no relationship with enable signal of Inverter)
19~20: Reserved
F07.17
Reserved
F07.18
Output terminal activeness setting
00
~
1FH
00
This parameter defines positive and negative logic of output terminal.
Positive logic: when output terminal is connected with corresponding common port, the terminal is active; when they are