109
KATANA S610M Inverter Specialized for Elevator Manual
Function Code
Name
Recommend set value
Remarks
F08.00
PG type
Set according to the
actual situation
F08.01
PG pulses per
revolution
Set according to the
actual situation
F08.02
PG direction of
rotation
Set according to the
actual situation
Table 7-12 special function codes set of CAN communication speed control
Function Code
Name
Recommend set value
Remarks
F00.02
Operating mode
selection
2
Speed control operation mode of
CAN communication
F02.00
Delay time of starting
0.50s
F02.01
Delay time of brake
release when starts
0.50s
F02.02
Maintaining time of
zero-speed starting
0.80s
Adjust based on comfort level when
elevator starts
F02.05
Daley time of braking
when stops
0.50s
F02.06
Maintaining time of
zero-speed when stops
0.50s
F02.07
Release delay of
operating contactor
0.50s
F03.00
Multi-speed 0
0
Decide based on design
F03.01
Multi-speed 1
Re-leveling speed
F03.02
Multi-speed 2
Creeping speed
F03.03
Multi-speed 3
Emergency speed
F03.04
Multi-speed 4
Inspection speed
F03.05
Multi-speed 5
Normal low speed
(speed of single level)
F03.06
Multi-speed 6
Normal medium speed
(speed of double level)
F03.07
Multi-speed 7
Normal high speed
(speed of multi-level)
F03.17
Multi-speed
inspection&Maintenance
selection
4
Multi-speed ins&maintenance
operation
F05.00
Rapid deceleration when
stops
0.35 m/s
3
Decide based on design
F05.01
Acceleration
0.55 m/s
2
F05.02
Rapid acceleration at the
0.35 m/s
3