![Katana S610M User Manual Download Page 133](http://html1.mh-extra.com/html/katana/s610m/s610m_user-manual_3606458133.webp)
103
KATANA S610M Inverter Specialized for Elevator Manual
Terminal No.
Meaning
R2A-R2C
Relay ouput signal: running at zero-speed
A+
Encoder differential frequency dividing output A+/OC output
phase A
B+
Encoder differential frequency dividing output B+/OC output
phase B
A-
Encoder differential frequency dividing output A-
B-
Encoder differential frequency dividing output B-
GND
Common port of frequency dividing output
7.4.2 Parameters Set
For CAN communication distance control mode, set of general function codes are showed as table 7-8 and special
function codes are showed as table 7-9.
Table 7-8 general function codes set of CAN communication distance control
Function Code
Name
Recommend set value
Remarks
F00.01
Control mode
selection
Set according to the
actual situation
F00.04
Rated speed of
elevator
Set according to the
actual situation
F00.06
Mechanical
parameters of the
motor
Set according to the
actual situation
F00.07
Maximum output
frequency
Set according to the
actual situation
F01.00
Rated power of the
motor
Set according to the
actual situation
Motor nameplate parameter
F01.01
Rated voltage of the
motor
Set according to the
actual situation
F01.02
Rated current of the
motor
Set according to the
actual situation
F01.03
Rated frequency of
the motor
Set according to the
actual situation
F01.04
Rated speed of the
motor
Set according to the
actual situation
F06.00
zero-speed start P
200
Adjusting according to the actual
operational aspect, normally use
factory settings.
F06.01
zero-speed start I
100
F06.02
ASR1-P
20.0
F06.03
ASR1-I
0.200
F06.04
ASR1 output filter
0
F06.05
ASR2-P
20.0
F06.06
ASR2-I
0.200