94
KATANA S610M Inverter Specialized for Elevator Manual
7.2.1 Basic wiring diagram
Figure 7-2 Multi-speed operation operating wiring diagram
In figure 7-2, "()" is for setting of programmable terminals. Meanings of terminals are shown in table 7-1:
Figure 7-1 Meanings of Mmulti-speed operation terminal
Terminal
symbol
Meaning
X1
Input terminal (X1) signal: Enabled (can be connected to
safety circuit)
X2
Input terminal (X2) signal: Fault resetting command
X3
Input terminal (X3): Upward command
X4
Input terminal (X4): Downward command
X5
Input terminal (X5) signal: Multi-speed command 1
X6
Input terminal (X6) signal: Multi-speed command 2
X7
Input terminal (X7) signal: Multi-speed command 3
R1A-R1C Relay output signal: during operation
R2A-R2C Relay output signal: during zero-speed operation
R3A-R3C
R3A-R3B
Relay output signal: Error output
(R3A-R3C refers to normal open output, R3A-R3B refers to
normal close output)
A+
Encoder differential frequency dividing output A+/OC output
phase A
B+
Encoder differential frequency dividing output B+/OC output
phase B
KM1
Elevator Controller
KM
M
PG
Encoder Feedback
X1(ENA)
X2(RST)
X3(UP)
X4(DN)
X5(MS1)
X6(MS2)
X7(MS3)
R1A,R1C
R2A,R2C
U
V
W
R3A,R3B,R3C
Power Input
R
S
T
S610M
Enable Open the Brake
Zero-speed Running
Error
A+
B+
A+
B+
A-
B-
A-
B-
0V