KATANA S610M Inverter Specialized for Elevator Manual
Figure 6-5 Input terminal activeness setting
When BIT is set to 0, it refers to positive logic; when it is set to 1, it refers to negative logic.
For example: if X1
~
X4 and X9 need positive logic, X5
~
X8 need negative logic, settings are as follows:
The logic state of X1
~
X4 is 0000, which corresponds to 0 in hexadecimal code, and LED units digit displays 0; The logic state of
X5
~
X8 is 1111, which corresponds to F in hexadecimal code, and LED tens digit displays F; The logic state of X9 is 0, which
corresponds to 0 in hexadecimal code, and LED hundreds digit displays 0. Meanwhile F07.15 should be set to 0F0. How to set the
parameter follows the below Table 2-4:
Table 6-4 The corresponding relation between binary setting and LED digit display
Binary setting
Hexadecimal
BIT3 BIT2 BIT1 BIT0
0
0
0
0
0
0
0
0
1
1
0
0
1
0
2
0
0
1
1
3
0
1
0
0
4
0
1
0
1
5
0
1
1
0
6
0
1
1
1
7
1
0
0
0
8
1
0
0
1
9
1
0
1
0
A
1
0
1
1
B
1
1
0
0
C
1
1
0
1
D
1
1
1
0
E
1
1
1
1
F
Hundreds digit
Tens digit
Units digit
BIT0: positive & negative logic definition of X1
BIT1: positive & negative logic definition of X2
BIT2: positive & negative logic definition of X3
BIT3: positive & negative logic definition of X4
BIT0: positive & negative logic definition of X5
BIT1: positive & negative logic definition of X6
BIT2: positive & negative logic definition of X7
BIT3: positive & negative logic definition of X8
BIT0: positive & negative logic definition of X9
BIT1: positive & negative logic definition of X10