KATANA S610M Inverter Specialized for Elevator Manual
There are 8 keys in total on the handheld operation panel. 6 keys are for setting or modifying the inverter
parameters, and the other 2 keys are for auxiliary functions, “RUN” and “STOP/RES”.
Table 4-2 Functions list of the operation panel
Key
Name
Function
PRG
Program/Exit
Enter or exit the programming status.
ENTER
Function/Data
Enter sub-menu or confirm data
△
Increment
Increment data or function code
▽
Decrement
Decrement data or function code
>>
Shift
Select modified bit of the data under editing state;
Shift to display the status parameter under other states.
SELECT
Multifunction
Under the operation panel control mode, double click
the “Select” key to start the motor, click the key once
to stop the motor.
When the inverter is shut down, press the key to reset
the current error.
DISP
RUN
Operating
Start the motor under operation panel control
STOP/RES
Stop/Reset
Press the key to stop the motor under operation panel
control
When the inverter is shut down, press the key to reset
the current error.
4.1.3 Status display of the operation panel
Statuses of the operation panel are displayed as shutdown status, operating status, error status, and function code
editing status etc.
1)
Shutdown status display
When the inverter is in shutdown state, shutdown status parameters are displayed on the operation panel.
Meanwhile the indicators “Run” and “Fwd/Rev” are off. When key “
” is pressed, the shutdown status
>>
parameters would be circularly displayed (defined by function code F13.05).
2)
Operating status display
After the inverter receives a valid operating command, it starts operation and the operating status parameters are
displayed on the operation panel. Meanwhile the indicator “Run” is on, and whether “Fwd/Rev” is on or off is
determined by the actual operating direction. When key “
” is pressed, the operating status parameters would be
>>
circularly displayed (defined by function code F13.05).
3)
Error status display
When the inverter detects an error signal, it would enter into error alert state. The indicator “Fault” is on, and the
error code is displayed with blinking. When key “>>” is pressed, the shutdown parameters and error code would
be circularly displayed. The error can be reset either by the control terminal or through “STOP/RES” key on the
operation panel. If the error continues, its error code is continuously displayed.
4)
Function code editing status display
In the state of shutdown, operating or error, when key “PRG” is pressed, the inverter enters into editing state (if
user password is set, please refer to F00.00 description). The editing state is displayed by two-level menus in light
of the following sequence: function code group or function code # → function code parameters. When “ENTER”
key is pressed, the inverter enters into the state of function parameters display. Parameters can be saved by
pressing “ENTER” key, and exit the menu by pressing “PRG”.