88
KATANA S610M Inverter Specialized for Elevator Manual
Chapter 7 Application Guide of Elevator
This chapter introduces in detail the basic steps of system design and setting method of function codes when using
S610M series inverter as part of elevator application system.
7.1 Basic debugging steps
7.1.1 System wiring and analysis
It is highly recommended that users comprehensively and symmetrically analyze practical application
requirements before designing the electrical schematic diagram of elevator system.
Basic configuration of elevator application when using S610M inverter is as shown in figure 7-1:
Figure 7-1 Basic configuration of elevator application
7.1.2
Setting of basic system parameters
1. Correctly set the model of traction machine and control mode (F00.01).
2. Correctly set relevant parameters of traction machine (Group F01).
3. Correctly set rated elevator speed (F00.04) and mechanical parameters of the motor (F00.06) according to
elevator demands and motor parameters.
4. Correctly set encoder parameters (Group F08) according to encoder of the traction machine.
5. Set input/output terminal parameters (Group F07) according to actual wiring conditions.
6. Set parameters according to actual operation mode.
Multi-speed operation mode of terminals:
Please set speed parameters (Group F03) and start & stop
parameters (Group F02) according to elevator’s actual demand and elevator controller. And set
acceleration/deceleration parameters (Group F05) according to elevator speed.
Operation mode of terminal analog value (Reserved):
Please set analog input curve (Group F04) and
analog input parameters (Group F07) according to elevator’s actual demand and elevator controller. Set
the acceleration/deceleration parameters in Group F05 to the maximum value. In this way, S610M
inverter can follow elevator controller’s speed commands at the fastest speed.
Multi-speed operation mode of CAN Communication:
Please set speed parameters (Group F03) and
start & stop parameters (Group F02) according to elevator’s actual demand and elevator controller. And
set acceleration/deceleration parameters (Group F05) according to elevator speed.
M
PG
Speed feedback
Weighing signal
(Retain)
Car
Counterweight
Controller
S610 M
Input terminal
Input
Power supply
Output terminal