19
KATANA S610M Inverter Specialized for Elevator Manual
LED tens digit: action selection for
auto reset interval error
0: no action
1: action
LED hundreds digit: reserved
F09.01
Error screen selection 1
LED
units
digit:
SCI
communication
error
screen
selection (reserved)
LED tens digit: contactor error
screen selection
LED hundreds digit: EEPROM
error screen selection
LED thousands digit: reserved
0: not screened. Error reported and
shutdown.
1: not screened. Error alert and
continues operation.
2: screened
1
0000
×
F09.02
Error screen selection 2
LED units digit: input phase loss
error screen selection
LED tens digit: output phase loss
error screen selection
0: not screened. Error reported and
shutdown.
1: not screened. Error alert and
continues operation.
2: screened
1
00
×
F09.03
Optimized
mode
selection
LED units digit: Prohibit to select
the optimization protection of
encoder wire-broken.
0: Start the optimization protection
of encoder wire-broken.
1:
Forbid
the
optimization
protection of encoder wire-broken.
LED tens digit: Power on and
Auto-tuning
selection
of
synchronous motor.
0:Start power on and auto-tuning of
synchronous motor.
1:Forbid power on and auto-tuning
of synchronous motor.
Note: F08.00=2 invalid
LED hundreds digit: Large tuning
selection of poweon CD angular
deviation
0: Turn on tuning
1: Prohibit tuninng
LED thousands digit: Cancel mode
selection of torque slope when
stopping.
0: No PI mode
1: PI mode
1
0
×