KATANA S610M Inverter Specialized for Elevator Manual
Function code
Name
Recommend set value
Remarks
F06.10
Zero-speed torque
limit value
180%
F06.11
ACR-P(No-start
current loop P)
1000
F06.12
ACR-I(No-start
current loop I)
640
F06.13
ACR-P0(Start
current loop P)
2000
F06.14
ACR-I0(Start
current loop I)
640
F08.00
PG type
Set according to the
actual situation
F08.01
PG the number of
pulses per
revolution
Set according to the
actual situation
F08.02
PG direction of
rotation
Set according to the
actual situation
Table 7-6 Setting of special function codes
Function Code
Name
Recommend set value
Remarks
F00.02
Operating mode
selection
1
Terminal analog value operation mode
F02.02
Maintaining time of
zero-speed starting
1.00s
Adjusting according to comfort level
when elevator starts
F04.00
Curve selection
0
AI2 select curve 1
F04.01
Curve 1 max.
analog reference
100.00%
Adjust according to the actual
situation, normally using factory
parameters.
F04.02
The corresponding
given frequency of
curve 1 max. analog
reference
100.00%
F04.03
Curve 1 min.
analog reference
0.00%
F04.04
The corresponding
given frequency of
curve 1 min. analog
reference
0.00%
F05.00
Rapid deceleration
when stops
9.999m/s
3
Set acceleration to maximum, then
inverter can follow elevator
controller’s speed command.
F05.01
Acceleration
9.999m/s
2
F05.02
Rapid acceleration
at the beginning
9.999m/s
3