11
KATANA S610M Inverter Specialized for Elevator Manual
synchronous motor
confirmed
F01.14
Initial angle of
synchronous motor
0
~
359.9°
0.1°
0
×
F01.15
Initial angle of Z pulse
of synchronous motor
0
~
359.9°
0.1°
0
×
F01.16
Auto tuning of the
motor parameters
0: no action
1: action (motor in rotary state)
2: action (motor in static state 1)
3: action (motor in static state 2)
4: action (motor in static state 3)
1
0
×
F01.17
Motor-overload
protection factor setting
20.0
~
110.0%
0.1%
100.0
×
F01.18
Oscillation
inhibition
factor
0
~
100
1
20
○
F01.19
Gain compensation of
slip frequency
50.0
%
~250.0%
0.1%
100.%
×
F01.20
Static tuning coefficient
of synchronous motor
50
%
~100%
1
80%
Group F02 Start & Stop Control Parameters
F02.00
Delay time of starting
0.00~2.00s
0.01s
0.50
×
F02.01
Delay time of brake
release when starts
0.00~2.00s
0.01s
0.50
×
F02.02
Maintaining time of
zero-speed starting
0.00~4.00s
0.01s
0.80
×
F02.03
Starting speed
0.000~0.200m/s
0.001m/s
0.00
×
F02.04
Maintaining time of
starting speed
0.00~2.00s
0.01s
0.00
×
F02.05
Daley time of braking
when stops
0.00~2.00s
0.01s
0.50
×
F02.06
Maintaining time of
zero-speed when stops
0.00~4.00s
0.01s
0.50
×
F02.07
Release
delay
of
operating contactor
0.00~2.00s
0.01s
0.50
×
F02.08
Time of starting slope
0.00~2.00s
0.01s
0.00
×
F02.09
Delay
of
torque
revocation when stops
0~800ms
1ms
10ms
×
F02.10
Detection
time
of
contactor error
0.00~2.00s
0.01s
0.50
×
F02.11
Delay
of
operation
permission revocation
0~6999ms
1ms
0ms
×
F02.12
Reserved
F02.13
Open brake frequency
of none close loop
0.00~10.00HZ
0.01HZ
0.00
×