84
KATANA S610M Inverter Specialized for Elevator Manual
Function Code
Name
Setting Range
Factory Default
Value
Figure 6-17 Digital input status
This parameter is to display the on-off state of 10 terminals, X1~X10. “0” stands for the terminal in “Off”
state, while “1” stands for the terminal in “On” state.
F92.16
Digital output terminal status
000
~
1FH
00
Figure 6-18 Digital output status
This parameter displays the output status of switch terminal Y1 & Y2 and Relay 1 ~ 3. When there is a
signal output, the corresponding digits of F92.16 would be set to 1.
Hundreds digit
Tens digit
Units digit
BIT0: on-off state of terminal X1
BIT1: on-off state of terminal X2
BIT2: on-off state of terminal X3
BIT3: on-off state of terminal X4
BIT0: on-off state of terminal X5
BIT1: on-off state of terminal X6
BIT2: on-off state of terminal X7
BIT3: on-off state of terminal X8
BIT0: on-off state of terminal X9
BIT1: on-off state of terminal X10
BIT2: on-off state of terminal HV (basic pole
sealing)
Tens digit
Units digit
BIT0: signal status of terminal Y1
BIT1: signal status of terminal Y2
BIT2: closing status of relay 1
BIT3: closing status of relay 2
BIT0: closing status of relay 3