KATANA S610M Inverter Specialized for Elevator Manual
Error
Code
Error
Description
Possible Causes
Solutions
100
Max. speed of actual
operation of elevator
can not reach the set
value,
and
the
elevator
cannot
perform the optimal
operation condition.
Please reduce the
running
speed
(d.004) or increase
the
acceleration
(d.005).
E080
Slight motion
leveling error
Overpass leveling of Slight motion
leveling
Others
Reserved
Attentions:
Short circuit of brake resistor may damage the brake unit of the inverter.
Warning types that may happen to S610M is listed in table 8-2. For specific information please refer to the setting
of function codes in Group F09. If the failure is automatically removed during operation, the inverter will
accordingly restore to the condition before warning (except for warning of A017). Please refer to the description
of function codes in Group F09 for details.
Table 8-2 Warnings and countermeasures
Warning
Code
Warning
Type
Possible Causes of Warning
Countermeasures
A013
Inverter
overloaded
inaccurate motor parameters
restart auto tuning of motor parameters
the inverter is overloaded
Choose an inverter with larger rated
power
the DC-braking volume is too large
Decrease the DC-braking current, and
prolong the braking time.
the acceleration time is too short
Prolong the acceleration time.
the network voltage is too low
check the network voltage
the V/F curve is inappropriate
modify V/F curve and torque boost
value
A014
Motor
overloaded
incorrect setting of motor overload
protection coefficient
Set the overload protection coefficient
of motor correctly.
motor stalling or too large fluctuation
of motor load
check the load